-
Great Salt Lake Composition and Rare Earth Speciation Analysis GTO_data_depos...
We have conducted aqueous speciation analyses of the Great Salt Lake (GSL) brine sample (Table 1) and a mock geo sample (Table 2) spiked with 1 ppb Tb and 100 ppb Tb. The GSL... -
Design of an Airlift Bioreactor GTO_data_deposit_092017_AirLiftBioreactor.xlsx
An important consideration for the process design is cell immobilization-enabled flow-through operation. Large-scale biosorption relies on cells that are immobilized on a... -
Techno-Economic Assessment for Integrating Biosorption into Rare Earth Recove...
The current uncertainty in the global supply of rare earth elements (REEs) necessitates the development of novel extraction technologies that utilize a variety of REE source... -
Rare Earth Desorption Test with Citrate and Bicarbonate GTO_data_deposit_0920...
LBT (lanthanide binding tag) cells were grown overnight in LB media with 0.05% Amp. 1:100 subculture taken from overnights, grown for 2 hours. LBT was induced with 0.002%... -
Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1...
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous... -
Repetitive Regeneration of Media #1 in a Dynamic Column Extraction using Brin...
This data is from a regeneration study from a dynamic column extraction experiment where we ran a solution of REE's through a column of media #1 then stripped the REE's off the... -
Magnetic Test Loop Particle Retention Data for REE Extraction from Geothermal...
Measurements of particle extraction efficiency under various flow rate and magnetic power conditions Computed nanoparticle removal efficiency under various operating conditions... -
REE Sorption Study for Media #1 and Media #2 in Brine #1 and #2 at different ...
This data set shows the different loading capacities of Media #1 and Media #2 in a high and low salt content brine matrix at different liquid to solid ratio's. These data sets... -
Repetitive Regeneration of Media #1 in a Dynamic Column Extraction using Brin...
This data is from a regeneration study from a dynamic column extraction experiment where we ran a solution of REE's through a column of media #1 then stripped the REE's off the... -
REE Sorption Study for Media #1 and Media #2 in Brine #1 and #2 at different ...
This data set shows the different loading capacities of Media #1 and Media #2 in a high and low salt content brine matrix at different liquid to solid ratio's. These data sets... -
RN12 and RN30 Epidote anlayses NGDS Tier 3 Data, xlsx format RN12 & RN30 Epid...
Results for laser ablation measurement of rare earth elements and electron microprobe analysis of major elements in hydrothermal epidote. Laser ablation measurements were... -
Brine Stability Study Stability - Immediate, Brine Cal.xlsx
This is a study of the brine formulations that we were using in our testing were stable over time. The data includes charts, as well as, all of the original data from the ICP-MS... -
Brine Stability Study DOE - Brine Stability (1).xlsx
This is a study of the brine formulations that we were using in our testing were stable over time. The data includes charts, as well as, all of the original data from the ICP-MS... -
REE Sorption Study for Media #1 and Media #2 in Brine #1 and #2 at different ...
This data set shows the different loading capacities of Media #1 and Media #2 in a high and low salt content brine matrix at different liquid to solid ratio's. These data sets... -
Magnetic Nanofluid Rare Earth Element Extraction Process Report, Techno Econo...
This GDR submission is an interim technical report and raw data files from the first year of testing on functionalized nanoparticles for rare earth element extraction from... -
Brine Stability Study Stability - 48hr I, Clean Cal.xlsx
This is a study of the brine formulations that we were using in our testing were stable over time. The data includes charts, as well as, all of the original data from the ICP-MS... -
Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1...
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous... -
Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1...
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous... -
Improved Rare Earth Element Sorption from Simulated Geothermal Brines: Effect...
A study exploring sorption and stripping characteristics of sorption media when simulated geothermal brines are degassed or not degassed. Experiments were done at 70degC. The... -
Repetitive Regeneration of Media 1 after REE Sorption from Brine 1 at 70C Reg...
This dataset shows the ability of media #1 to be loaded with REE's, stripped of the REE's sequestered, regenerated, and reused over many cycles. These are the data charts...